dam ›› 2016, Vol. 0 ›› Issue (3): 65-.

Previous Articles     Next Articles

Detection and analysis based on high density resistivity method for Gaolehan reservoir

YANG Yang, WANG Fan-hua, HE Yong-jun and FAN Guang-ya   

  1. Dam Safety Management Department, Nanjing Hydraulic Research Institute
  • Received:2016-02-03 Revised:2016-04-08 Online:2016-06-08 Published:2016-06-08

高勒罕水库大坝高密度电法检测与分析

杨阳1,2,王范华3,何勇军1,2,范光亚1,2   

  1. 1.南京水利科学研究院大坝安全与管理研究所,江苏 南京,210029;
    2.水利部大坝安全管理中心,江苏 南京,210029;
    3.中电投蒙东能源集团有限责任公司水库管理中心,内蒙古 霍林郭勒,029200
  • 作者简介:杨 阳(1985- ),男,博士,研究方向为水工建筑物安全监控与应用。
  • 基金资助:
    南京水科院院基金(Y716002、Y716009、Y716010、Y716013),国家自然科学基金(51609149)

Abstract: High density resistivity method can reveal inside information of a dam which takes a short time and low cost. At the same time, the method will not cause damage to the dam. For this reason, it was to detect the cracks on downstream slope of Gaolehan dam. Combined with dam monitoring data and site inspection information, the crack cause of downstream slope was analyzed and identified, and some remedial measures were given.

Key words: high density resistivity method, dam, leakage, detection

摘要: 高密度电法检测方法不需要对大坝进行开挖破坏,成本低、时间短,能够揭示大坝内部信息。为此采用高密度电法对高勒罕水库土石坝下游坡的裂缝情况进行检测,同时结合监测资料和现场巡查等信息,分析判断大坝下游坡的开裂原因,并提出处治措施。