ISSN 1671-1092 CN 33-1260/TK

• 国外科技信息 • 上一篇    

Taum Sauk抽水蓄能工程系列报道(I)—Taum Sauk抽水蓄能电站上库溃坝过程及原因分析

崔弘毅 编译   

  1. 国家电力监管委员会大坝安全监察中心,浙江杭州 310014
  • 出版日期:2010-10-28 发布日期:2010-10-28

Report on Taum Sauk pumped storage project——failure process and reason analysis

CUI Hong-yi   

  • Online:2010-10-28 Published:2010-10-28

摘要: 2005年12月14日,因设计、施工不当,仪器方面的失误和人为失误等众多原因,美国Taum Sauk抽水蓄能电站上水库失事,自此停止运营。主要介绍失事的过程和原因,供参考。

Abstract: A variety of design and construction flaws, instrumentation error, and human errors contributed to a catastrophic failure of the upper reservoir on Dec 14, 2005. Ever since, the project has been out of operation. This paper introduced the failure process and cause reasons were analysed, for reference.