Analysis on the cause reason of cracks at Shuikou hydropower house

ZHU Yan-hua   

  • Online:2010-06-28 Published:2010-06-28

水口电站主厂房裂缝成因探析

朱艳华   

  1. 福建水口发电有限公司,福建福州 350800

Abstract: There are many cracks in concrete structure of Shuikou hydropower house such as slab of generator floor, bent frame column and joins between bracket support and slab. Based on photographic data, image correction and mapping of cracks, the spatial distribution characteristics of cracks were obtained. Then combined with load conditions and structural characters of Shuikou hydropower house, the analysis result showed the cracking reasons were dynamical forces caused by water flow impulse pressure of spiral case and mechanical vibration of generating units.