dam ›› 2013, Vol. 0 ›› Issue (4): 49-53.

Previous Articles     Next Articles

Analysis on seepage safety of the spillway gate at Zhaoshandu water diversion project

ZHENG Jian-yuan   

  1. Zhejiang Shanxi Economic Development Co., Ltd.
  • Received:2013-06-20 Online:2013-08-31 Published:2013-08-31

赵山渡引水工程泄洪闸渗漏问题的安全状况分析

郑建媛   

  1. 浙江珊溪经济发展有限责任公司,浙江 温州 325000
  • 作者简介:郑建媛(1972-),女,工程师,主要从事赵山渡引水工程的供水调度和工程管理工作。

Abstract: In October 2004, leakage was found in sluice gates of Zhaoshandu water diversion project. At the beginning of 2008, the leakage had developed into flow jet. It’s clear that the leakage problem was getting worse. This paper introduces the seepage control system and the development process of leakage. The safety conditions were checked by calculation, the hidden defects of seepage stability were pointed out and the safety status was comprehensively analyzed. At the same time, the specific measures for the anti-seepage treatment were introduced, for reference.

Key words: Zhaoshandu water diversion project, seepage, safety, analysis

摘要: 2004年10月,发现赵山渡引水工程泄洪闸存在渗漏,2008年初发展为大流量的喷水、射流,渗漏问题恶化的趋势十分明显。介绍了该工程防渗系统构成和渗漏问题的发展过程,对渗漏情况下的工程安全状况进行了复核计算,指明了渗流稳定方面存在的安全隐患,综合分析了该工程的安全状况。同时,对该工程防渗处理的具体措施进行了简要介绍。

关键词: 赵山渡引水工程, 渗漏, 安全, 分析