ISSN 1671-1092 CN 33-1260/TK

• 资料分析 • 上一篇    下一篇

抽水蓄能电站库盆渗漏量监控指标的研究

傅春江,李君军,王玉洁   

  1. 国家电力监管委员会大坝安全监察中心,浙江杭州 310014
  • 出版日期:2011-08-28 发布日期:2011-08-28

Research on seepage monitoring indicators for the reservoir basin of pumped storage power station

FU Chun-jiang, LI Jun-jun and WANG Yu-jie   

  • Online:2011-08-28 Published:2011-08-28

摘要: 为评判抽水蓄能电站库盆的渗漏量大小,提出了渗漏量分级监控指标——无故障监控指标和极限监控指标。介绍了基于综合渗透系数法和裂缝渗流法的无故障监控指标计算方法,并采用计算建筑物的排水能力来制定极限监控指标。通过具体实例阐述了分级监控指标的应用。

Abstract: To evaluate the seepage at reservoir basin of pumped storage power station, monitoring indicators of two grades were advanced, i.e. faultless monitoring indicators and limit monitoring indicators. This paper, based on comprehensive permeability coefficient method and crack seepage method, introduced the calculation method for faultless monitoring indicators, as well, drainage capacity of structures was used to set the limit monitoring indicators. At last, example was presented to show the application of the monitoring indicators.